All-in-one weather transmitter - WXT520

 

Overview

 
With the world becoming increasingly sensitive to weather and climate, it is important to measure the
weather accurately. The Vaisala Weather Transmitter WXT520 offers the solution to measure barometric
pressure, humidity, precipitation, temperature, and wind speed and direction - all with one instrument!

Features

 
 ►   Measures 6 most essential weather parameters as WXT510
 ►   Accurate and stable
 ►   Low power consumption - works also with solar panels
 ►   Compact, light-weight
 ►   Easy to install
 ►   No moving parts
 ►   Vaisala Configuration Tool for PC
 ►   USB connection
 ►   Housing with mounting kit IP66

 

Applications


Compact and lightweight, the WXT520 is suitable for weather stations, dense networks, buildings, golf courses, marinas, harbors, and hotels - almost anywhere where real time weather data is needed.  Accurate and reliable data provided to you early enough can increase safety to life and property.

How does WXT520 do it?


To measure wind speed and direction, the WXT520 has the Vaisala WINDCAP® sensor that uses ultrasound to determine horizontal wind speed and direction. The array of three equally spaced transducers on a horizontal plane is a Vaisala specific design, which ensures accurate wind measurement from any horizontal wind direction without blind angles and corrupted readings.
 
Barometric pressure, temperature, and humidity measurements are combined in the PTU module using capacitive measurement for each parameter. It is easy to change the module without any contact with the sensors.
 
Precipitation measurement is based on the Vaisala RAINCAP® sensor. For details, please see the next page.
Get a quote for a via our online sales enquiry form or call us!
 
 
 

Specifications

 

Measurement

Units

Operational Range

Resolution

Accuracy

Specification Range

Wind Speed

m/s
0-60 m/s
0.01
0 ... 35 m/s  ±0.3 m/s or ±3%, whichever is greater, 36 ... 60 m/s ±5%

Wind Direction

Deg
0-360°
-
±3°
250 ms response time

Rainfall

cumulative accumulation after latest automatic or manual reset

 

mm
0.01 mm, 0.001 inches
5%*
-
-

Rainfall duration

counting each ten-second increment when droplet detected

 

s
-
10 s
-
-

Rain intensity

one-minute running average in ten-second steps

 

mm/h
inches/h
0-200 mm/h (broader range with reduced accuracy
0.1 mm/h, 0.01 inches/h
-
0-200 mm/h (broader range with reduced accuracy

Barometric pressure

hPa
600 ... 1100 hPa
-
±0.5 hPa at 0-30 °C (+32- +86 °F)
±1 hPa at -52- +60 °C (-60- +140 °F)

Air temperature

°C
-52- +60°C (-60- +140°F)
-
Accuracy at +20 °C (+68°F)  ±0.3 °C (±0.5°F)

Relative humidity

%RH
0 ... 100 %RH
-
±3 %RH within 0 ... 90 %RH
±5 %RH within 90 ... 100 %RH

Operating temperature

-52- +60 °C (-60- +140 °F)

Storage temperature

-60- +70 °C (-76- +158 °F)

Input voltage

5 … 32 VDC

Typical power consumption

3 mA at 12 VDC (with defaults)

Heating voltage

5 … 32 VDC (or AC, max. 30 VRMS)

Serial data interface

SDI-12, RS232, RS485, RS422, USB adapterr

Housing

IP65

Housing with mounting kit

IP66

Electromagnetic compatibility

complies with EMC standard EN61326-1; Industrial Environment

IEC standards

IEC 60945/61000-4-2 … 61000-4-6

 

Due to the nature of the phenomenon, deviations caused by spatial variations may exist in precipitation readings, especially in short time scale. The accuracy specification does not include possible wind induced error.
 

More information:

Windsonic wind brochure
Windsonic wind iss15 manual
80SPC solar radiation brochure
105 Hand Pyranometer brochure
HMP155 Humidity and Temperature brochure
HMP155 Humidity and Temperature users guide
ML2 Soil Moisture brochure
ML2 Soil Moisture users guide
SM200 Soil Moisture brochure
SM200 Soil Moisture manual
PTB110 Barometric Pressure brochure
PTB110 Barometric Pressure users guide
RG12 Raingauge brochure
WXT520 weather transmitter brochure
WXT520 user guide
WXT520 wiring guide
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright 2009 Pacific Data Systems Pty Ltd.  All Rights Reserved.

Home | About Us | Technical | Downloads | Business/Careers | News | Clearance | Support | Sales | Contact | Sitemap |