Portable Water Quality Monitoring

 
Along with manufacturing In-situ Water Quality Monitoring Stations, Pacific Data Systems also supplies portable water quality monitors for field testing. We are the Australian distributor for the Ponsel range of portable water quality monitoring equipment which allows fast and easy measurements of water quality while out in the field.
 
Get a quote for a via our online sales enquiry form or call us!
 

· · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · ·

 

ACTEON 3000 terminal equipped with its AQUACLIP 100

 
Using the ACTEON 3000 terminal equipped with its AQUACLIP 100 measurement probe allows you to measure up to 6 parameters simultaneously :

►   pH,
►   Temperature,
►   Conductivity,
►   Redox,
►   Dissolved oxygen,
►   Depth.

Shipped in a universal watertight case, it comes with ACTEWIN, a software to make maximum use of ACTEON 3000 and to operate AQUACLIP 100 probe directly from your PC.

The product address customers ranging from Governmental or private organisations in charge of environmental monitoring of water resources, to Producers of drinking waters, fish farms, shell farms, and of course Education.  
 
 

ACTEON 3000

 
The ACTEON 3000 portable terminal, a combination of reliability and technical performance, was designed to achieve the most accurate water quality analyses. Equipped with a wide backlit digital screen and user friendly drop down menu.

The universal case is totally watertight (IP 67), thus ensuring complete safety when carrying out measurements.
 
►    High memory capacity : recording more than 32 000 measurement batches,
►    High autonomy : up to 3 months of continuous measurements possible,
►    Supply : 4 standard Alkaline batteries,
►    Multilingual display: FR, EN, ES, DE,
►    Case : watertight and floating,
►    Pulse output for remote control of external equipment,
►    Compact and light (600 gr),
►    Universal case with AQUACLIP 100 probe.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

pH, Redox, conductivity, temperature, dissolved oxygen sensor probesWhite sensor

►   pH/Redox,
 

Grey sensor

► Conductivity/Temperature,
 

Red sensor

►   Dissolved oxygen
       (automatic temperature 
       adjustment).

 

AQUACLIP 100

 
Using the AQUACLIP 100 measurement probe allows you to measure up to 6 parameters simultaneously : Temperature, conductivity, pH, Redox, Dissolved oxygen and Depth.

 

 ►   Manual connection of the sensors by simple "clip",
 ►   Fast connection to ACTEON 3000, a computer or any other instrument using SDI12 protocol(automatic water sampler, water quality station),
 ►   Ballasted cap, exchangeable for stainless steel,
 ►   Pocket size for maximum user convenience length = 420 mm, diameter = 40 mm),
 ►   Flexibility in use : its independent connection cable length allows adjusting cable length according to your needs.
 
 

Ponsel portable kit

Ponsel kit with all accessories incl Acteon 3000 and Aquaclip 100

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

The complete case comes with the following items:

 
1. Aquaclip 100 probe with its sensors connected & its protection case
2. Acteon 3000 portable terminal
3. Ballasted strainer
4. Aquaclip probe cable (15, 20 or 30m depending on client's order)
5. Actewin adapter (SDI12/RS232)
6. Calibration standard pH 4,01 ; pH 7,01
7. Calibration standard for conductivity 1413mS/cm ; 12,88 mS/cm

Ponsel kit with all accessories incl Acteon 3000 and Aquaclip 100 in carry case

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
8. Calibration standard for ORP 240mV
9. Electrolyte oxymetric standard for D.O. sensor
10. Sodium sulphite (Zéro O2)
11. Case with 6 spare membranes for the dissolved oxygen sensor
12. CD ROM with ActeWin software and user manual in pdf-format
13. Acteon and Aquaclip connection cables for adapter SDI12/RS232
14. Waterproof obturating plugs for sensors disconnected (2)

 

More information: