Overview

 
A fully automatic, simple to use breath alcohol measuring instrument for use by traffic police, in industry, medicine - and in many other applications. On account of its accuracy the alcolmeter® SD-400 is approved and used in various countries as an evidential instrument. To use, simply switch on, attach a mouthpiece and tell the subject to blow. His or her alcohol level is shown just seconds later on a large, easy to read display. The reading is then stored in memory, with date and time, for later download to a computer system for management purposes. An optional data-logging system (e.g. operator, subject, sex and age) is also available. A reusable plastic sample cup may be used as an alternative to the single-use mouthpiece tube for fast, non-invasive PASS/FAIL precursory testing. Alternatively, connect the instrument to a PC loaded with OnLineTM-400, for a low-cost 'evidential' system.
 
Get a quote for a via our online sales enquiry form or call us!
 

 

Specifications

 

Fuel Cell Sensor

 ►    High specificity to alcohol, unaffected by other possible breath contaminants.
 

Warm-up Time

 ►   The instrument is ready for use within 15 seconds of switch on, at any, temperature.
 

Measuring Range

 ►   Normally 0.02 to 2.00mg/litre BrAC. An over-range indication is given at higher levels.
 

Analytical Response Time

 ►    Normally within 30 seconds; but within 5 seconds at zero alcohol levels.
 

Temperature Range

 ►    From -5C to +40C, for optimum operation.
 

Recalibration

 ►    Every six months, using either a wet-bath simulator or Alcocal® gas standard.
 

Recovery Time

 ►   Typically 10 seconds at zero alcohol; 60 seconds at 0.35mg/litre BrAC; 4 minutes at 2.00mg/litre.
 

Memory Capacity

 ►    500 tests as standard, expendable up to 5,000 on demand.
 

Power Supply

 ►    5 new AA cells give at least 3,000 breath tests. Two stage low power warning system.
 

Radio Frequency Immunity

 ►    Exceeds requirement of EN 50082-1.
 

Shock/Vibration

 ►    Impact resistant ABS: meets IEC 68-2-27 Part 2.1 Test EA and IEC 68-2-6 Port 2.1 Test FC.

Dimensions

 ►    169 x 80 x 39mm [instrument only]; 190 x 90 x 65mm [in leather pouch].
 

Weight

 ►    Approximately 525g [including batteries and leather pouch].
 

More information:

Instrumentation for Breath Alcohol Measurement brochure

Alcoblow brochure

Alcolmeter 500 brochure

SD-400 brochure

SD-400P brochure

I-8000 brochure

Lion Software brochure

Wall Mounted Alcolizer brochure

Able printer 1300 guide

OnLine-400 3.0 handbook

SD-400 Ver5 Manual

Lion Laboratories

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Copyright 2009 Pacific Data Systems Pty Ltd.  All Rights Reserved.

Home | About Us | Technical | Downloads | Business/Careers | News | Clearance | Support | Sales | Contact | Sitemap |